What causes about 75% of amputations?
Vascular disease, chiefly arteritis and/or diabetes.
What must be protected from pressure when fitting a patient with arteritis?
Any bypass-graft route.
What fitting does a femur ending less than 5 cm below the greater trochanter resemble?
Fitting for hip disarticulation.
How does transfemoral amputation affect hip muscle balance?
It weakens extension and adduction, leaving flexors and abductors relatively dominant.
What should socket design preserve regarding the middle gluteal muscle?
Its effectiveness in stabilizing the pelvis.
What methods manage edema in a closed residual limb, and when is bandaging reapplied?
Elastic bandaging, tubular elastic stockinette, or an elastocompressive sleeve is used; bandaging is reapplied when the prosthesis is removed.
Which areas does clinical assessment cover when evaluating a prosthesis patient?
History, observation, residual-limb condition, circulation and sensation, joint and muscle function, functional ability, and measurements.
What information must the workshop record communicate?
Measurements and reference points, expected tightening, socket type, components, and alignment instructions.
How does an exoskeletal prosthesis carry load?
Through its peripheral socket and cosmetic structure.
What feature distinguishes an endoskeletal prosthesis?
It uses an internal modular tube system for alignment adjustment and standardized component replacement.
What is the socket’s primary role for a residual limb?
It receives the residual limb and enables coaptation and force transmission.
Where does a quadrilateral socket place the ischium?
On a posterior shelf.
Which socket type may use a valve-generated vacuum?
A total-contact socket.
What does suspension do during the swing phase of a prosthesis?
It keeps the socket in contact with the residual limb and prevents it from coming off.
What interface does a transfemoral liner provide, and why is it not always used?
It interfaces the residual limb with the socket; substantial muscle coverage often makes it unnecessary.
Which residual-limb or patient conditions indicate a liner under the LPP?
Short or flaccid residual limbs, fragile skin, invaginated scars, bilateral amputations, upper-limb impairment, or a need for stronger suspension.
What sensory and mechanical benefits does a silicone liner provide?
It provides good proprioception, control, containment, and adhesion.
What do socket-to-knee connectors generally allow adjustment of?
Alignment.
How far can the alignment system translate in the frontal or sagittal plane?
15 mm.
During heel strike, what position is the knee in?
Extension.
What must a prosthetic knee combine for safe, efficient walking?
Stability in extension and mobility in flexion.
What activities should a prosthetic knee support?
Sitting, safe standing and walking, varied cadences and terrain, stair and slope negotiation, and sports.
What does the instantaneous center of rotation determine at the knee?
The knee’s equilibrium.
What defines the locked knee’s basic movement and how is it released?
It is a monoaxial knee locked in extension and released by cable or lever.
What happens to the stabilizing brake during swing and weight-bearing?
It is free during swing and locks the knee under weight-bearing, even with up to about 15° of flexion.
In the LPPR, what role do VI4 knee variants play with base prostheses?
They are optional variants added to a PI02, PI03, or PI04 base prosthesis and may receive AI4 additions.
Which patients are offered a locking knee for maximum safety?
Older, weak, bilateral, or temporarily fitted patients.
What gait does a locking knee accept to maximize safety?
A stiff-legged gait.
What does prosthetic alignment describe?
The spatial position of the prosthesis’s different components.
Where does the frontal-plane load line pass through the prosthesis?
The socket’s medial third, the knee’s midpoint, the ankle’s center, and the space between the first and second toes.
What are the three main origins of transfemoral gait defects?
Alignment, socket, and patient factors.
When are prosthetic additions offered to a patient?
Only when the patient feels they are useful.
How does a passive one-way valve differ from active vacuum systems?
It expels air at each step without a pump, producing weaker vacuum.
What extends the service life of soft foam used for an aesthetic covering?
A stretchable, tear-resistant, water-repellent polyurethane coating.
What remains intact during knee disarticulation, and what is removed?
The bones remain intact, and only the leg is removed.
What is one advantage of knee disarticulation for prosthetic control?
It provides improved prosthetic control.
Who developed the Canadian prosthesis, and where?
McLaurin developed it in Toronto.
Which EU regulation governs custom-made prostheses as medical devices?
EU Regulation 2017/745.
What documentation must a custom-made prosthesis have?
A manufacturing file.
How does an osteomyoplasty differ from a myoplasty?
It sutures the femoral end to the periosteum and preserves muscle continuity.
Which residual-limb level best balances leverage, function, energy cost, and knee-component space?
The middle third.
Which code denotes a very long femoral residual limb?
PI 04.
What hip extension is needed for walking?
About 10°.
Which hip flexors remain intact after transfemoral amputation?
The psoas and iliacus.
What role can preserved middle and small gluteal muscles provide?
Possible hip stability.
When may postoperative mobilization traditionally begin, and when may current practice begin it?
Traditionally after 3 to 4 days, or the following day in current practice.
When do patients generally enter a rehabilitation center after surgery?
About 15 days after surgery.
How should compression be applied to a transfemoral residual limb?
It should extend in a spica over the opposite iliac crest and decrease from distal to proximal.
What hip position helps counter contracture tendencies after amputation?
Hip extension, both in bed and during rehabilitation.
What residual-limb and skin details does the assessment record?
Amputation level, useful length, shape, bony prominences, skin and scar condition, and soft-tissue quality.
What functional abilities are considered during assessment and renewal?
Autonomy, transfers, balance, walking distance, assistive devices, existing-prosthesis walking, and satisfaction.
What is a reliable European reference for measurement projection?
Projection from the perineum.
Which components are included in a prosthesis?
Structural type, socket, socket-to-knee connection, knee, shank or cosmetic covering, shank-to-foot junction, foot, and optional suspension or additions.
Which prefixes identify optional variants and additions in traditional LPPR coding?
VI identifies optional variants; AI identifies additions.
What code replaced LPPR alphanumeric codes for some listed products?
A seven-digit numerical LPP code.
What are the three main parts of a socket?
A proximal brim, a body, and a base.
Who developed the quadrilateral socket, and in what year?
Canty, 1953.
What two sources can provide prosthetic suspension?
An external system or the socket’s shape, supports, counter-supports, and contact.
How is the simple suspension harness positioned and adjusted?
It passes over the opposite shoulder and is adjusted with Velcro and a buckle.
What can excessive tension in a simple suspension harness do?
It can impair walking.
What is one purpose of the rigid strap joining a double suspension harness?
It prevents the same-side shoulder strap from slipping.
When is a molded silicone liner indicated?
For an atypical residual-limb shape or when greater durability is needed.
Which residual limbs and activity levels suit silicone liners?
Low to high activity levels and fleshy, toned residual limbs without bony prominences.
How is a wooden exoskeletal socket provisionally bonded to the knee during fitting?
At four opposing points.
How is a laminated socket with suspension or partial contact attached to its cap?
It is fitted into and bonded onto the cap.
What feature is most often included in an endoskeletal knee assembly?
An adjustment system.
Which muscles are essential for mobilizing a prosthetic knee?
The hip flexors and gluteus maximus.
When is a locked knee prescribed for a patient with poor prosthesis control?
It is prescribed when the patient has poor control of the prosthesis.
What provides stance stability in a polycentric knee without a brake or lock?
Its center of instantaneous rotation lies behind the load line in extension.
What produces flexion and extension return in a mechanical knee system?
Hip flexion produces knee flexion, and a mechanical return, usually a spring, restores extension.
In an LPPR code beginning VI4Z, what does the following letter identify?
The knee’s control family.
What determines prescription of an LPPR locking knee?
The medical assessment, particularly safety and low activity.
Which LPPR code identifies the VI4ZS25 knee?
Hydraulic swing-and-stance regulation.
Which LPPR code identifies the C-Leg, and which identifies its revision?
VI4ZS26 identifies the C-Leg; VI4ZS28 identifies its revision.
Which patients suit a stabilizing brake with extension return assistance?
Patients who lack confidence or are receiving their first prosthetic fitting.
What walking conditions suit a pneumatic knee?
Indoor and outdoor walking at slow or moderate speeds.
Which knee suits varied walking speeds and sports?
The hydraulic knee.
Where is the knee joint center positioned relative to the sagittal load line?
Five to ten millimeters posterior to it.
What initial flexion is given to the socket?
About five degrees, accounting for any irreducible flexion contracture.
What lateral rotation is given to the prosthetic foot?
About six to ten degrees.
During transfemoral prosthetic stance, which muscles help lock the knee at initial contact?
The gluteus medius and hip extensors.
Which footwear-related factors can cause alignment-related gait defects?
A worn shoe or an unsuitable heel height.
Which socket-related factors can cause transfemoral gait defects?
Excessive size, improper shape, or poor fit to residual-limb volume.
Which patient-related factor can contribute to transfemoral gait defects?
Acquired habits.
What is the maximum weight for the two reimbursed rotation adapter models?
100 kg.
What do prosthetic shock absorbers absorb during ground contact?
Impacts at initial ground contact or flat landing.
How does the Harmony E2 regulate prosthetic vacuum?
It regulates vacuum continuously, even while standing still.
From what material and form is soft foam cut for an aesthetic covering?
A prefabricated block of polyurethane.
Which three factors determine the choice of soft foam for an aesthetic covering?
The side, the residual limb’s proximal diameter, and the type of knee.
How much extra circumference is added when shaping foam to a patient’s measurements?
1.5 to 2 cm.
Which materials form the thigh, seated-knee, and lower-leg aesthetics in a two-part semi-rigid covering?
A plastic shell beneath the socket forms the thigh and seated-knee aesthetics; prefabricated foam forms the lower-leg aesthetic.
How does Gritti amputation improve terminal support?
It fixes the prepared posterior surface of the patella to the femur.
What shape does the upper part of a knee-disarticulation contact socket have?
It is cylindrical above and triangular with a posterior base below.
Which framework governs reimbursement for prosthetic care in France?
The LPPR.
What is required for the first fitting and renewals of prostheses under the LPPR?
Prior approval is required for the first fitting and renewals.
What patient education do electronic knees and pumps require?
Patients need guidance on recharging, operating modes, warning signals, and mandatory checkups.
Answer 54 questions on Prothèse transfémorale : suspensions et genoux.
1. Approximately what proportion of amputations have a vascular cause, chiefly arteritis and/or diabetes?
2. A patient with arteritis has a residual limb whose volume continues to change after initial stabilization, and a bypass graft runs beneath a potential socket contact area. What should the fitting team do?
Go over the full study guide for Prothèse transfémorale : suspensions et genoux.
Read the study guide →Upload your class notes and Revizly writes your flashcards in about a minute.
Flashcard maker