Prothèse transfémorale : suspensions et genoux Practice Quiz (54 questions)
All questions and answers
1. Approximately what proportion of amputations have a vascular cause, chiefly arteritis and/or diabetes?
About 75%
About 50%
About 90%
About 25%
About 75%
Explanation
Vascular causes account for about 75% of amputations, with arteritis and/or diabetes being the main examples. The other percentages underestimate or overestimate that stated share.
2. A patient with arteritis has a residual limb whose volume continues to change after initial stabilization, and a bypass graft runs beneath a potential socket contact area. What should the fitting team do?
Monitor volume changes but allow socket pressure over the graft route
Monitor volume changes and identify and protect the graft route from pressure
Protect the graft route but treat limb volume as stable after stabilization
Fix the socket dimensions and assess the graft route after fitting
Monitor volume changes and identify and protect the graft route from pressure
Explanation
In arteritis, residual-limb volume may continue to vary after stabilization, and the bypass-graft route must be identified and protected from fitting pressure. Treating volume as stable misses the stated change; disregarding graft pressure or delaying assessment risks pressure on the graft.
3. A patient’s femur ends 4 cm below the greater trochanter. What fitting implication follows from this residual-limb length?
Fitting resembles a lower-third amputation because the prosthetic knee has extra space
Fitting favors a long transfemoral lever because walking forces transmit effectively
Fitting resembles hip disarticulation because walking forces transmit poorly and the capsule is affected
Fitting remains a routine transfemoral fitting because the capsule is unaffected
Fitting resembles hip disarticulation because walking forces transmit poorly and the capsule is affected
Explanation
A femur ending less than 5 cm below the greater trochanter transmits walking forces poorly and affects the capsule, so fitting resembles that for hip disarticulation. The other choices misapply the advantages of a longer residual limb or deny the stated effects.
4. After transfemoral amputation, a patient with a short femur tends to hold the hip in flexion and abduction. Which muscle-balance change best explains this pattern?
Weakened flexion and adduction leave extensors and abductors relatively dominant
Weakened extension and adduction leave flexors and abductors relatively dominant
Weakened extension and abduction leave flexors and adductors relatively dominant
Weakened flexion and abduction leave extensors and adductors relatively dominant
Weakened extension and adduction leave flexors and abductors relatively dominant
Explanation
Transfemoral amputation weakens hip extension and adduction while flexors and abductors remain relatively dominant, encouraging flexion and abduction, especially with a short femur. The alternatives reverse or misassign the affected and relatively dominant muscle groups.
5. A prosthetist is designing a socket for a transfemoral amputee and wants to preserve a muscle important for stabilizing the pelvis. Which muscle should the design accommodate?
Middle gluteal muscle
Hamstring group
Greater gluteal muscle
Adductor group
Middle gluteal muscle
Explanation
The middle gluteal muscle remains important for pelvic stabilization, so socket design should preserve its effectiveness. The greater gluteal muscle is associated chiefly with hip extension, while the hamstrings and adductors are different muscle groups.
6. A patient with a closed residual limb removes the prosthesis during the day. Which approach helps control edema and should be repeated after removal?
Apply compression to the opposite limb to improve circulation in the residual limb
Use an open-ended provisional socket to replace compression after removal
Apply elastic compression to stimulate venous return, then reapply it after prosthesis removal
Use a noncompressive dressing to protect the skin, then leave it unchanged after removal
Apply elastic compression to stimulate venous return, then reapply it after prosthesis removal
Explanation
For a closed residual limb, elastic bandaging, tubular elastic stockinette, or an elastocompressive sleeve stimulates venous return and reduces edema; bandaging is reapplied when the prosthesis is removed. A noncompressive dressing does not provide the stated compression, compression of the opposite limb targets the wrong limb, and an open-ended socket is associated with early fitting.
7. A patient is 18 days post-amputation, and the residual limb remains open under a dressing. Which fitting approach matches this stage?
Immediate fitting with a plaster socket made on the operating table
Provisional fitting with a contact socket as healing progresses
Early fitting with an open-ended provisional socket and no interface
Definitive fitting after residual-limb volume has stabilized
Early fitting with an open-ended provisional socket and no interface
Explanation
Early fitting begins 15 days to 3 weeks after amputation and uses an open-ended provisional socket without an interface. Immediate fitting refers to a plaster socket made on the operating table, while contact sockets are associated with provisional fitting as healing progresses.
8. A patient is about three weeks post-amputation, the residual limb is healing over the coming weeks, and its volume is still changing. Which fitting plan is appropriate?
Begin definitive fitting once the first temporary socket is made
Begin provisional fitting with a contact socket as healing progresses
Begin definitive fitting because three weeks have elapsed
Continue early fitting with an open-ended socket and no interface
Begin provisional fitting with a contact socket as healing progresses
Explanation
Provisional fitting generally begins around three weeks after amputation with a contact socket while healing progresses over 4 to 8 weeks. Definitive fitting is considered when residual-limb volume has stopped changing and requires LPPR prior approval; an open-ended socket without an interface characterizes early fitting.
9. During an initial prosthetic assessment, which set of domains provides the broad clinical picture needed to guide prosthesis design?
Residual-limb shape and skin, functional ability, and measurements, without joint or muscle assessment
History and observation, residual-limb and skin findings, vascular and sensory status, joint and muscle function, function, and measurements
Observation and walking ability, with residual-limb morphology and circulation assessed separately
History and measurements, with vascular and sensory findings deferred until after fitting
History and observation, residual-limb and skin findings, vascular and sensory status, joint and muscle function, function, and measurements
Explanation
Clinical assessment spans patient history and spontaneous observation, residual-limb morphology and skin, vascular and sensory status, joint and muscle function, functional ability, and measurements. A measurements-only approach, a function-only approach, or an assessment omitting key domains is incomplete.
10. An orthotist is preparing a workshop record for a new socket. Which content best enables the workshop to make and align the prosthesis as intended?
Patient history and clinical observations, with components and alignment inferred later
Measurements with reference points, expected tightening, socket type, components, and alignment instructions
Measurements, components, and confidential clinical details, without socket or alignment guidance
Measurements and socket type, with tightening and alignment left for workshop judgment
Measurements with reference points, expected tightening, socket type, components, and alignment instructions
Explanation
The workshop record communicates measurements and their reference points, expected tightening, socket type, components, and alignment instructions in clear, exhaustive wording while respecting professional confidentiality. Omitting reference points, tightening, or alignment leaves essential fabrication guidance unspecified.
11. A prosthetist wants a transfemoral prosthesis whose alignment can be adjusted through an internal modular tube system and whose components can be replaced with standardized parts. Which structural type best fits this need?
A fixed-shell prosthesis
A peripheral-load prosthesis
An exoskeletal prosthesis
An endoskeletal prosthesis
An endoskeletal prosthesis
Explanation
An endoskeletal prosthesis uses an internal modular tube system that supports alignment adjustment and standardized component replacement. Peripheral load-bearing describes an exoskeletal design, while robustness and few post-finishing adjustments are associated with that design rather than the requested modular adjustability.
12. When coding a transfemoral prosthesis under the traditional LPPR system, a clinician adds an optional prosthetic foot variant to the basic device. Which code prefix and level identify that variant?
AI8
VI8
A seven-digit numerical LPP code
VI4
VI8
Explanation
Traditional LPPR optional variants use the prefix VI, and a foot variant is coded at level 8 as VI8. AI marks an addition, VI4 identifies a knee variant, and seven-digit numerical codes belong to the newer LPP system.
13. What is the primary role of a transfemoral socket in relation to the residual limb and prosthesis?
To suspend the prosthesis externally without transmitting forces
To control knee flexion and extension during the walking cycle
To receive the residual limb, enable coaptation and force transmission, and influence comfort and walking
To connect the shank to the prosthetic foot and provide cosmetic coverage
To receive the residual limb, enable coaptation and force transmission, and influence comfort and walking
Explanation
The socket receives the residual limb and supports coaptation and force transmission, while influencing comfort, stability, and walking quality. Knee control is the role of the prosthetic knee, cosmetic coverage concerns the shank, and external suspension is one socket suspension approach rather than the socket's overall function.
14. During a socket assessment, the ischium and/or ischiopubic ramus is contained within the socket rather than resting on a posterior shelf. Which socket concept is being used?
A conventional suspension socket
A quadrilateral socket
A total-contact socket
An ischial-containment socket
An ischial-containment socket
Explanation
An ischial-containment socket includes the ischium and/or ischiopubic ramus within the socket. In a quadrilateral socket, the ischium rests on a posterior shelf; conventional suspension and total contact describe other socket characteristics.
15. A prosthetist is shaping an IRC socket to hold a patient's femur in natural adduction. Which set of three-point control locations should guide the design?
Beneath the greater trochanter, above the ischiopubic ramus, and along the posterior femoral shaft
Above the ischial tuberosity, beneath the greater trochanter, and along the medial femoral shaft
At the iliac crest, around the patella, and along the lateral tibial shaft
Beneath the ischial tuberosity and ischiopubic ramus, above the greater trochanter, and along the lateral femoral shaft
Beneath the ischial tuberosity and ischiopubic ramus, above the greater trochanter, and along the lateral femoral shaft
Explanation
IRC control positions the femur in natural adduction using support beneath the ischial tuberosity and ischiopubic ramus, above the greater trochanter, and along the lateral femoral shaft. The other combinations shift or misidentify these landmarks, or include landmarks outside the transfemoral socket.
16. A patient’s socket is designed to contact the entire residual-limb surface and may use a valve-generated vacuum for suspension. Which suspension concept does this describe?
An ischial-containment socket
A total-contact socket
A muscle-adhesion socket
A conventional socket
A total-contact socket
Explanation
A total-contact socket contacts the whole surface and may use a valve-generated vacuum. Muscle-adhesion suspension relies on proximal fit and muscle contraction, while conventional suspension is external; ischial containment describes how the ischium is positioned.
17. During the swing phase of gait, what is the primary role of suspension in a transfemoral prosthesis?
Reduce pressure on the residual limb during standing
Maintain socket contact and prevent it from coming off
Support the body’s weight during the stance phase
Control knee flexion during the swing phase
Maintain socket contact and prevent it from coming off
Explanation
Suspension maintains contact between the socket and residual limb and prevents the socket from coming off during swing; it also supports rotational control and the patient’s sense of security. Weight-bearing support, pressure reduction, and knee-flexion control are related prosthetic concerns, but they do not define suspension.
18. A patient’s prosthesis is suspended by close contact along the sides of the residual limb and muscle bulging that creates congruence. The patient finds the repeated muscle activity exhausting. Which mechanism explains this fatigue?
A pump must continuously maintain negative pressure
Repeated muscle contraction and relaxation require substantial energy
A sealing ring must repeatedly compress the limb
A distal pin must repeatedly engage and disengage
Repeated muscle contraction and relaxation require substantial energy
Explanation
Muscle-adhesion suspension relies on close lateral contact and muscle bulging, while alternating contraction and relaxation makes it energy-intensive. Active vacuum, distal pin engagement, and a sealing ring describe other suspension mechanisms.
19. A patient’s socket contacts the entire residual-limb surface and uses a valve to create virtual vacuum, reinforced by muscle bulging. Which suspension concept is being used?
Active-vacuum suspension
External-belt suspension
Total-contact suspension
Muscle-adhesion suspension
Total-contact suspension
Explanation
Total-contact suspension distributes pressure over the entire residual-limb surface and uses virtual vacuum created by a valve, reinforced by muscle bulging. Muscle adhesion relies on close lateral contact, active vacuum is maintained by a pump, and a belt is an external suspension method.
20. A prosthetist is choosing a suspension for a patient with a short residual limb, fragile skin, limited hand strength, and a strong need for security. Which approach best follows the selection rule?
Weigh the limb, skin, dexterity, arm strength, activity, and security needs together
Choose according to skin condition and disregard functional ability
Choose according to activity level without considering security needs
Choose according to residual-limb length and disregard other patient factors
Weigh the limb, skin, dexterity, arm strength, activity, and security needs together
Explanation
Suspension selection depends on several interacting factors, including limb length, skin condition, gestural autonomy, upper-limb strength, activity, and the need for security. Relying on a single factor overlooks the individualized nature of the decision.
21. What is the role of a transfemoral liner, which is not required for every patient?
Distal connector that links the limb to the socket
External belt that suspends the prosthesis
Interface between the residual limb and the socket
Structural shell that contains the residual limb
Interface between the residual limb and the socket
Explanation
The liner is the interface between the residual limb and the socket, although it is not systematic in transfemoral prostheses because muscular coverage is often substantial. The socket shell, an external belt, and a distal connector serve different roles.
22. A patient has a short, flaccid residual limb, fragile skin, and limited upper-limb function. Under the stated LPP indications, which choice is appropriate to consider?
No liner, because upper-limb impairment argues against one
A liner, given the limb, skin, and upper-limb factors
Silicone specifically, because all indicated patients require it
A liner only if the patient has a high activity level
A liner, given the limb, skin, and upper-limb factors
Explanation
LPP indications include short or flaccid residual limbs, fragile skin, and impairment of one or both upper limbs, among other situations. The indication does not require high activity or mandate a particular liner material.
23. A patient needs strong control and proprioception, and also has scars for which improved healing and release of adhesions would be beneficial. Which liner material best matches these priorities?
Prefabricated liner material of any type
Silicone
Thermoformable polyurethane
Copolymère gel
Silicone
Explanation
Silicone is relatively thin and rigid, providing good proprioception, control, containment, and adhesion, and it may promote healing and scar release. Copolymer emphasizes comfort and skin tolerance, while polyurethane is particularly suited to distributing stress and protecting fragile tissue.
24. A patient has fragile, irregular tissue, and the clinical priority is distributing stress and protecting the skin rather than maximizing proprioception. Which liner material is the best match?
Silicone
Copolymère gel
A material selected for maximum proprioception
Thermoformable polyurethane
Thermoformable polyurethane
Explanation
Thermoformable polyurethane closely conforms to the limb, and its flow helps distribute stresses and protect fragile tissue, making it suitable when skin protection takes priority over proprioception. Silicone is associated with stronger proprioception and control, while copolymer mainly emphasizes comfort and skin tolerance.
25. What is the primary role of a socket-to-knee connection device in a prosthesis?
To suspend the prosthesis from the residual limb and control socket rotation
To receive the socket, connect it to the knee, and generally permit alignment adjustments
To regulate the knee’s flexion resistance and set the walking cadence
To select the socket material according to skin risk and limb-volume changes
To receive the socket, connect it to the knee, and generally permit alignment adjustments
Explanation
Connection devices receive the socket, join it to the knee, and generally allow alignment adjustments; their configuration depends on prosthesis structure and socket material. Suspension, knee resistance, and material selection are separate functions.
26. During a prosthetic fitting, a clinician needs a temporary alignment system that allows frontal translation by 12 mm and rotation in 8° increments. Which device best fits this task?
A heavy alignment system used for fitting before its settings are transferred
A permanent connector that adjusts rotation in 18° increments
A lightweight socket attachment retained after fitting without transferring settings
A pyramidal system that provides translation and inclination during walking
A heavy alignment system used for fitting before its settings are transferred
Explanation
The alignment system permits frontal or sagittal translations of up to 15 mm and rotation in 8° increments, and is used during fitting before its settings are transferred. A pyramidal system does not provide translation, while 18° applies to abduction-adduction and flexion-extension.
27. An orthoprothetist combines components from two manufacturers. What practice addresses the responsibility and safety requirements for this assembly?
Record component references while using a common tightening value for all assemblies
Follow torque limits, maximum loads, and instructions, then record component references in the file
Rely on presumed compatibility and record the assembly only if a failure occurs
Observe torque limits but disregard maximum loads and manufacturer instructions
Follow torque limits, maximum loads, and instructions, then record component references in the file
Explanation
Combining components from different manufacturers makes the orthoprothetist responsible in case of failure, so torque limits, maximum loads, and instructions must be followed and references documented. Presumed compatibility or incomplete compliance does not satisfy these requirements.
28. A prosthetic-knee gait cycle is being reviewed. What should happen at the end of stance to help the user advance the limb?
The knee returns to extension to secure the transfer of body weight
The knee makes only a slight flexion to absorb the heel-strike impact
The knee begins approximately 30° of flexion to help the limb pass through
The knee returns to extension as the swing phase comes to an end
The knee begins approximately 30° of flexion to help the limb pass through
Explanation
At the end of stance, the knee initiates about 30° of flexion to help the limb pass through. Slight flexion absorbs heel-strike impact, while extension occurs to secure weight transfer and again at the end of swing.
29. A prosthetic-knee design is being evaluated for a user who needs to handle variable walking speeds and different terrain. Which expected function is most directly relevant?
Support for sitting and rising from a chair
Security during static standing and level walking
Assistance with ascending stairs and performing sports
Adaptation to different cadences and varied terrain
Adaptation to different cadences and varied terrain
Explanation
An expected knee function is accommodating variable cadence and varied terrain. Sitting, stair ascent, sports, and static or walking safety are also expected functions, but they do not specifically describe adaptation to cadence and terrain.
30. A technician examines a polycentric knee in full extension. Where should its instantaneous center of rotation be located, and what gait benefit follows from the linkage?
On the mechanical axis, low and behind the load line; translation lengthens the shank during swing
At the extended linkage axes’ intersection, low and in front of the load line; rotation shortens the shank during stance
On the mechanical axis, high and in front of the load line; rotation lengthens the shank during swing
At the extended linkage axes’ intersection, high and behind the load line; translation shortens the shank during swing
At the extended linkage axes’ intersection, high and behind the load line; translation shortens the shank during swing
Explanation
In a polycentric knee, the center of rotation is where the extended linkage axes intersect; in extension it lies high and behind the load line. The preceding translation shortens the shank during swing, whereas the mechanical-axis location describes a monoaxial knee.
31. A patient uses a monoaxial knee locked in extension during walking and releases it with a cable to sit down. Which trade-off is characteristic of this design?
Natural swing with automatic stair control but a need for app setup
Reliable stance security but a stiff gait, sometimes with circumduction
Free swing with load-triggered locking but a slow, cautious gait
Adaptable resistance with smoother walking but a need for charging
Reliable stance security but a stiff gait, sometimes with circumduction
Explanation
A locking knee is reliable and can be released for sitting, but its stiff gait may involve limping or circumduction. A load-activated brake is free during swing, while real-time adaptation and charging belong to microprocessor knees.
32. During assessment, a patient can guide the prosthesis through swing but needs extra security at heel strike. Which knee behavior best matches a stabilizing brake?
It measures gait continuously and adjusts resistance using a microprocessor
It stays locked in extension during walking and releases by cable
It is free under load and brakes only while the leg swings forward
It is free in swing and brakes under load, even with slight knee flexion
It is free in swing and brakes under load, even with slight knee flexion
Explanation
A stabilizing brake is free during swing and blocks the knee when weight is applied, even if it remains flexed by about 15 degrees. A permanent extension lock describes a locking knee, while sensor-based adjustment describes a microprocessor knee.
33. A user’s prosthetic knee must respond to changing walking speed and effort by adjusting resistance during both stance and swing. Which system provides this control?
A microprocessor knee using continuous measurements and real-time adjustment
A locking knee using a cable to release the extension lock
A stabilizing-brake knee using load to set stance resistance
A monoaxial knee with a fixed resistance set during fitting
A microprocessor knee using continuous measurements and real-time adjustment
Explanation
Microprocessor knees continuously measure variables such as angle, effort, and speed, then adjust stance and swing resistance in real time. A stabilizing brake responds to loading, while a locking knee relies on a mechanical lock.
34. A physician is deciding whether a patient meets the effective-prescription criteria for a C-Leg. The patient walks continuously for 2.3 km, reaches 4.2 km/h, descends a 16% slope, and descends stairs using alternating steps. What follows from these results?
The criteria are not met because the continuous distance is below 3 km
The criteria are not met because stair descent must use the same leading leg
The criteria are not met because the walking speed is below 5 km/h
The listed effective-prescription criteria are met
The listed effective-prescription criteria are met
Explanation
Effective C-Leg prescription requires more than 2 km continuously, speed above 4 km/h, descent of a slope of at least 15%, and alternating-step stair descent. The 3 km/h and 500 m thresholds concern access to the trial, not effective prescription.
35. When a knee is listed in the LPPR as a VI4 option, how is it incorporated into a prosthesis?
It is an AI4 base component to which a PI02, PI03, or PI04 knee is added
It is a required base component added to a VI4 prosthesis, with possible PI02 additions
It is a standalone product that replaces the PI02, PI03, or PI04 base prosthesis
It is an optional variant added to a PI02, PI03, or PI04 base prosthesis, with possible AI4 additions
It is an optional variant added to a PI02, PI03, or PI04 base prosthesis, with possible AI4 additions
Explanation
LPPR knees are optional VI4 variants added to a PI02, PI03, or PI04 base prosthesis, and AI4 additions may also be included. Treating VI4 as a standalone product confuses an optional variant with the base prosthesis.
36. An active patient is being considered for a microprocessor knee. Which set of findings and prescription conditions satisfies the listed trial and confirmation criteria?
Trial at least 3 km/h and over 500 m continuously for at least 15 days; confirmation over 2 km, over 4 km/h, 15% slope, alternating-step stairs, MPR, class I foot, and primary prosthesis
Trial at least 3 km/h and over 500 m continuously for at least 15 days; confirmation over 2 km, over 4 km/h, 15% slope, alternating-step stairs, MPR, class II or III foot, and primary prosthesis
Trial at least 3 km/h and over 500 m continuously for 10 days; confirmation over 2 km, over 4 km/h, 15% slope, alternating-step stairs, MPR, class II or III foot, and primary prosthesis
Trial over 4 km/h and over 2 km continuously for at least 15 days; confirmation at least 3 km/h, 500 m, 15% slope, alternating-step stairs, MPR, class II or III foot, and primary prosthesis
Trial at least 3 km/h and over 500 m continuously for at least 15 days; confirmation over 2 km, over 4 km/h, 15% slope, alternating-step stairs, MPR, class II or III foot, and primary prosthesis
Explanation
The trial requires at least 3 km/h, more than 500 m continuously, and at least 15 days; confirmation requires the higher distance and speed thresholds plus the specified slope, stair, MPR, foot-class, and primary-prosthesis conditions. The 4 km/h and 2 km values are confirmation thresholds, and the foot must be class II or III.
37. An older patient with weak muscles is being fitted with a prosthesis temporarily. Which knee option best prioritizes safety while accepting a stiff-legged gait?
A pneumatic knee
A stabilizing brake with extension assist
A locking knee
A hydraulic knee
A locking knee
Explanation
A locking knee is proposed for patients who are older, weak, bilaterally amputated, or temporarily fitted because it maximizes safety while accepting a stiff-legged gait. A hydraulic knee targets varied cadences, a stabilizing brake suits an unsure or first-time user, and a pneumatic knee supports smooth, low-energy walking.
38. A prosthesis user walks indoors and outdoors at a slow-to-moderate pace and values a smooth gait with low energy expenditure. Which knee best matches this profile?
A multiaxial knee with pre-flexion
A pneumatic knee
A locking knee
A hydraulic knee
A pneumatic knee
Explanation
A pneumatic knee suits indoor and outdoor walking at slow or moderate speed and promotes smooth, low-energy walking. A hydraulic knee is suited to varied cadences and sport, a locking knee prioritizes safety, and a multiaxial knee with pre-flexion helps with impact absorption and slope descent.
39. During frontal-plane alignment of a prosthesis, where should the load line pass through the knee and foot?
Through the posterior knee and the outer edge of the foot
Through the knee midpoint and the space between the first and second toes
Through the anterior knee and the centre of the heel
Through the knee midpoint and the space between the second and third toes
Through the knee midpoint and the space between the first and second toes
Explanation
In the frontal plane, the load line passes through the knee midpoint and the space between the first and second toes, as well as the inner third of the socket and ankle centre. The posterior knee and rear foot landmarks belong to the sagittal-plane alignment, while the other toe and heel locations do not match the frontal-plane line.
40. A clinician is beginning to assess alignment with a patient. Which sequence describes the required broad stages of the assessment?
Fabrication followed by static verification
Static verification followed by dynamic verification
Dynamic verification followed by static verification
Static verification followed by fabrication
Static verification followed by dynamic verification
Explanation
Alignment work with the patient proceeds from static verification to dynamic verification. Starting dynamically reverses the sequence, while fabrication is not one of the two patient-assessment stages.
41. While adjusting a prosthesis, a clinician has completed static alignment and is ready to proceed. Which sequence and recording practice should guide the remaining work?
Dynamic frontal, then sagittal, then slope-and-stair stance; change one parameter at a time and record each setting
Dynamic frontal, then sagittal, then slope-and-stair stance; change several parameters together and leave settings unrecorded
Dynamic frontal, then slope-and-stair stance, then sagittal; change one parameter at a time and record each setting
Dynamic sagittal, then frontal, then slope-and-stair stance; change one parameter at a time and record each setting
Dynamic frontal, then sagittal, then slope-and-stair stance; change one parameter at a time and record each setting
Explanation
After static alignment, the sequence is dynamic frontal, dynamic sagittal, and finally stance on slopes and stairs; only one parameter should be changed at a time and every setting recorded. The sagittal-first sequence reverses the prescribed order, while the other errors omit a final phase or undermine controlled, traceable adjustment.
42. When checking sagittal-plane alignment for a patient, where should the knee joint centre be positioned relative to the load line?
At the load line, with no offset
5° posterior to the load line
5 to 10 mm anterior to the load line
5 to 10 mm posterior to the load line
5 to 10 mm posterior to the load line
Explanation
In the sagittal plane, the knee joint centre is positioned 5 to 10 mm posterior to the load line, which passes in front of the knee. Placing it anterior or directly on the line reverses or removes the specified offset, while 5° is an angle associated with initial socket flexion rather than this distance.
43. A transfemoral prosthesis user develops an abnormal trunk movement during walking. Which broad categories should be considered as possible origins of the gait defect?
Socket, footwear, and walking-speed factors
Stance, swing, and balance factors
Alignment, knee, and foot factors
Alignment, socket, and patient factors
Alignment, socket, and patient factors
Explanation
Gait defects may originate from alignment, the socket, or the patient, and several causes can combine. Stance and swing are gait phases, while knee, foot, footwear, and speed are narrower considerations rather than the three broad categories.
44. During an assessment of a transfemoral prosthesis user's gait defect, the clinician has described when it occurs and in which plane. What should the clinician check next in the practical sequence?
Knee stiffness, extension response, and foot position
Patient strength, fear of falling, and compensatory habits
Socket fit, rotational stability, and pressure discomfort
Apparent limb length, footwear, and assistive devices
Apparent limb length, footwear, and assistive devices
Explanation
After describing the defect by timing and plane, the assessment first checks apparent length, footwear, and assistive devices. Patient factors and socket or knee-and-foot checks come later in the sequence.
45. A patient with a prosthesis is considering an added component that may improve comfort but would also add weight. What should guide whether it is proposed?
Whether it reduces weight compared with the base prosthesis
Whether the patient feels it would be useful
Whether it is compatible with the base prosthesis
Whether it provides any possible functional benefit
Whether the patient feels it would be useful
Explanation
Prosthetic additions can improve comfort or function but add weight, so they are proposed when the patient perceives a need for them. A possible benefit alone does not replace the patient's perceived utility.
46. A clinician compares two suspension systems: one expels air at each step without a pump, while the other actively generates vacuum. Which comparison is accurate?
The passive valve creates weak-to-moderate vacuum; active systems create stronger or more stable vacuum
The passive valve creates stronger or more stable vacuum; active systems create weak-to-moderate vacuum
The passive valve uses a pump at each step; active systems rely on body weight to expel air
Both systems expel air at each step without a pump and create similar vacuum
The passive valve creates weak-to-moderate vacuum; active systems create stronger or more stable vacuum
Explanation
A passive one-way valve expels air under body weight at each step without a pump, producing weak-to-moderate vacuum; active systems can create stronger or more stable vacuum. Reversing the vacuum levels confuses the systems' relative performance, while attributing a pump to the passive valve misstates its mechanism.
47. A prosthetic foam cover looks good initially but splits near the knee after repeated use. Which treatment would best extend its service life?
Apply an extensible, tear-resistant, water-repellent polyurethane coating
Apply a tear-resistant coating that does not stretch
Replace it with a rigid, non-extensible polyurethane coating
Apply a flexible coating that is not tear-resistant
Apply an extensible, tear-resistant, water-repellent polyurethane coating
Explanation
An extensible, tear-resistant, water-repellent polyurethane coating prolongs the life of soft foam, which otherwise wears quickly and may split at the knee. A rigid coating loses the needed flexibility, while the other alternatives omit either extensibility or tear resistance.
48. In a two-part semi-rigid cosmetic covering, which component provides the appearance of the thigh and the knee when seated?
The elastic strap connecting the socket
The plastic cup beneath the socket
The prefabricated foam for the leg
The fabric covering placed over the foam
The plastic cup beneath the socket
Explanation
The plastic cup beneath the socket shapes the thigh and knee appearance when seated, while prefabricated foam provides the leg’s appearance. The leg foam therefore has the wrong role, and the strap and fabric covering are not the component assigned this shaping function.
49. During a knee disarticulation, which description best captures what is removed and what is preserved?
The end of the femur is removed, while the kneecap is fixed to it
The leg is removed at the joint, while the bones remain intact
The lower femur is shortened, while the leg is removed below the joint
The leg and kneecap are removed, while the femur remains intact
The leg is removed at the joint, while the bones remain intact
Explanation
Knee disarticulation removes the leg through the joint while leaving the bones intact; the kneecap is generally preserved and the muscles are sutured together. Removing the femoral end describes Gritti amputation, and the other alternatives incorrectly add bone or kneecap removal.
50. A patient with a knee disarticulation has strong residual-limb leverage and can bear weight at the end of the limb, but fitting a prosthetic knee is difficult. Which explanation best accounts for this combination?
The piriform shape improves leverage but leaves little room for terminal loading
The short residual limb improves terminal loading but limits prosthetic-knee space
The long residual limb improves leverage but leaves little room for a prosthetic knee
The preserved muscles improve leverage but make terminal loading impractical
The long residual limb improves leverage but leaves little room for a prosthetic knee
Explanation
Knee disarticulation offers a long lever and possible terminal weight-bearing, but the limb’s length leaves little space for a prosthetic knee. A short limb is not the reason for this combination, and the piriform shape is associated with difficult donning rather than increased knee space.
51. Which prosthesis, developed by McLaurin in Toronto, provides stability without a locking mechanism for hip disarticulation or an extremely short residual limb at the greater trochanter?
A conventional prosthesis, stabilized by a mechanical lock
The Gritti prosthesis, stabilized by terminal weight-bearing
A contact prosthesis, stabilized by supra-condylar suspension
The Canadian prosthesis, stabilized by a double recurvatum
The Canadian prosthesis, stabilized by a double recurvatum
Explanation
McLaurin’s Canadian prosthesis is used for hip disarticulation and very short residual limbs at the greater trochanter; it has no lock and relies on a double recurvatum for stability. Supra-condylar suspension pertains to knee-disarticulation fitting, while terminal loading and a mechanical lock do not describe this design.
52. A clinic fabricates a custom prosthesis for a patient. Which documentation and post-delivery obligations apply to this device?
A manufacturing file, component traceability, patient training, and a reimbursement claim
A prescription, component traceability, a patient notice, and mandatory electronic-device revisions
A prescription, prior authorization, a patient notice, and renewal documentation
A manufacturing file, component traceability, a patient notice, and medical-device vigilance
A manufacturing file, component traceability, a patient notice, and medical-device vigilance
Explanation
A custom-made prosthesis is a medical device under EU Regulation 2017/745, requiring a manufacturing file, component traceability, a notice for the patient, and medical-device vigilance. Prior authorization concerns reimbursement, while training and mandatory revisions concern electronic knees and pumps.
53. A patient is fitted with an electronic knee and pump. Which education should the care team provide?
Prescriptions, prior agreements, reimbursement codes, and renewal timing
Manufacturing records, component traceability, patient notices, and vigilance reporting
Charging, operating modes, warning signals, and required revisions
Socket fit, suspension choice, knee alignment, and rehabilitation scheduling
Charging, operating modes, warning signals, and required revisions
Explanation
Patients using electronic knees and pumps need instruction on recharging, modes, warning signals, and required revisions. Reimbursement paperwork, fitting and rehabilitation, and manufacturing traceability are related but address different aspects of prosthetic care.
54. In a static stance, a prosthetic knee’s instantaneous center of rotation (ICR) lies well behind the load line. Which adjustment would improve knee stability under the stated rule?
Move the load line behind the ICR.
Move the load line forward so the ICR lies farther behind it.
Bring the ICR closer to the load line.
Move the ICR farther backward relative to the load line.
Move the load line forward so the ICR lies farther behind it.
Explanation
Static stability improves when the ICR is farther behind the load line, and the load line must not pass behind the ICR; moving the load line forward increases that separation. Moving the ICR farther backward describes the wrong adjustment, placing the load line behind the ICR violates the rule, and bringing the ICR closer reduces stability.